TNC17570: Correct logic in TNZBLOCK to acquire an AME correctly

PTF TNC17570
Title Correct logic in TNZBLOCK to acquire an AME correctly
Product TNC175 Date Opened 2/26/2001 
Status Closed Date Closed 3/4/2001  Fixed 200
Group Level2  Related NRS6252  Bucket?
PTF
NAME TNZNCS TNZBLOCK                                    
VER 0364 58F0,1004                   L    R15,AMENEXT   
REP 0364 45E0,BEF8                   BAL  R14,*PATCH*   
*                                                       
NAME TNZNCS TNZPATCH                                    
VER 0EF8 BEF8,BEFA,BEFC,BEFE         VERIFY PTF NOT ON  
VER 0F00 BF00,BF02                                      
REP 0EF8 1211                        LTR  R1,R1         
REP 0EFA 4780,A2D4                   BZ   BLK1402       
REP 0EFE 58F0,1004                   L    R15,AMENEXT   
REP 0F02 07FE                        BR   R14 (RETURN)  
*                                                       
VER 10F7 00                          VERIFY PTF NOT ON  
REP 10F7 AF                          TNC17570 IS NOW ON

Commentary

Monday, February 26, 2001 at 04:55:58 pm   
This PTF checks to see if the AME chain is exhausted while requesting an AME from the available chain. If so then another AME block is acquired and more AME's are added to the available chain.