TND40176: Leave DFBABEND bit on while Dispatcher completes DFB termination

PTF TND40176
Title Leave DFBABEND bit on while Dispatcher completes DFB termination
Product TND401 Date Opened 2/27/1995 
Status Closed Date Closed 3/23/1995  Fixed 409
Group Level2  Related Bucket?
PTF
PreReq TND40173  CoReq
NAME DIRECTOR TNDDISP
VER 0896 94EF,B003                     NI   DFBFLAG,255-DFBABEND
REP 0896 4700,B003                     NOP  DFBFLAG
VER 103C 9604,B003                     OI   DFBFLAG,DFBDONE
REP 103C 45E0,CD6C                     BAL  R14,*PATCH*

NAME DIRECTOR TNDPATCH
VER 0D6C CD6C,CD6E,CD70,CD72,CD74
VER 20A2 00                            VERIFY PTF NOT ON
REP 0D6C 9604,B003                     OI   DFBFLAG,DFBDONE
REP 0D70 94EF,B003                     NI   DFBFLAG,255-DFBABEND
REP 0D74 07FE                          BR   *RETURN*
REP 20A2 C9                            TND40176 IS NOW ON

Commentary

Tuesday, January 16, 2001 at 03:15:05 pm   
TND40173 implemented logic to avoid potential recursive calls to DISP during Abend processing. This PTF causes DISP to leave the DFBABEND bit on so that subsequent TND routines can test to determine if abnormal termination is going on.